+8676023136186
Battery for UPS computer

Battery for UPS computer

Spill proof best battery for ups computer has a characteristic of high discharge rate, wide operating temperatures, long service life and deep discharge recover.

image006

image004 image004

PHYSICAL SPECIFICATION

Nominal Voltage
Nominal Capacity (10HR)

12V

100Ah

image008

Dimension

Length
Width
Container Height
Total Height

331±2mm (13.03 inches)

172±2mm (6.77 inches)

216±2mm (8.50 inches)

222±2mm (8.74 inches)

Weight

Approx. 28.5 Kg ±3% ( 62.83lbs)

Standard Terminal

B3(Bolt-and-nut terminal)

Bolt Type: M6

image010image012


Shimastu NP series AGM VRLA Batteries have been developed as general purpose batteries,they're valve-regulated lead acid batteries with high quality. Absorbed Glass Mat(AGM) separators & high purity raw materials, featured by perfectly good performance and reliable standby service life.
Features:
1.Non-spillable
2.Sealed and Maintenance-free Operation
3.High Quality and High Reliability
4.Less gassing,low Self-discharge
5.Low internal resistance
6.Long design life up to 8 years in float service at 25℃ (77 0F )­

ELECTRICAL SPECIFICATION

Characteristics

Discharge curves @ 25℃ (77 °F)

Capacity

10 hour rate (10A)

5 hour rate (17A)

3 hour rate (25A)

1 hour rate (55A)

100Ah

85Ah

75Ah

55Ah

image013

Capacity affected
by temperature

40℃ (104 0F)

25℃ (77 0F)

0℃ (32 0F)

102%

100%

85%

Max Discharge Current

1000A(5 Sec)

Short Circuit Current

2150A

Internal Resistance

Full charged battery (25℃,77 0F) 6.8mΩ

Constant Voltage
Charge

Cycle

Initial Charging Current less than 25A

Voltage 14.1~14.4V at 25℃ (77 0F )

Temperature Coefficient –30mV/℃

Standby

No limit on Initial Charging Current

Voltage 13.5~13.8V at 25℃ (77 0F )

Temperature Coefficient –20mV/℃

CONSTANT CURRENT DISCHARGE RATING  A@25℃

F.V/TIME

10MIN

15MIN

30MIN

1HR

3HR

5HR

8HR

10HR

20HR

1.60V

240.4

181.0

108.1

62.0

28.3

18.9

12.7

10.6

5.51

1.65V

218.9

173.0

103.9

59.7

27.4

18.4

12.5

10.4

5.44

1.70V

198.9

162.1

99.5

57.4

26.7

17.9

12.4

10.3

5.36

1.75V

181.7

150.8

94.7

55.0

25.8

17.5

12.2

10.1

5.30

1.80V

165.0

139.2

90.6

53.0

25.0

17.0

12.0

10.0

5.25

CONSTANT POWER DISCHARGE RATING   WATT PER CELL@25℃

F.V/TIME

10MIN

15MIN

30MIN

1HR

3HR

5HR

8HR

10HR

20HR

1.60V

397.7

316.5

196.4

116.6

54.0

36.6

25.0

20.9

10.8

1.65V

379.4

307.0

190.8

112.8

52.6

35.6

24.6

20.6

10.7

1.70V

351.0

291.8

184.4

109.1

51.3

34.8

24.2

20.3

10.6

1.75V

326.3

275.5

177.3

105.2

50.1

34.0

23.9

20.0

10.5

1.80V

301.5

258.0

171.4

102.0

48.5

33.2

23.7

19.7

10.4


Hot Tags: battery for ups computer, China battery for ups computer manufacturers, suppliers, factory, solar deep cycle gel battery 150ah 12v, 12 volt interstate marine battery, 120ah deep cycle lithium battery, custom lithium ion battery, 2v1000ah battery, electric scooter lead acid battery

With the advancement of technology, many people rely on electronic devices, including computers, in their daily work and life. Battery for UPS computer require reliable batteries to ensure safe, uninterrupted operation. Its most important feature is capacity. The capacity of the battery determines how long the UPS can provide power during a power outage. Therefore, it is very important to choose a high-capacity battery. Typically, it has a battery capacity ranging from 6V to 12V, depending on the type of UPS system.


Features

There are two main types of batteries used in our products, sealed lead-acid batteries and lithium-ion batteries. Sealed lead-acid batteries are the most commonly used battery type for UPS computers due to their low cost, reliable performance, long service life, and good temperature resistance. Lithium-ion batteries, on the other hand, have higher energy density, are lighter in weight, and take up less space, making them suitable for small UPS systems. However, lithium-ion batteries are more expensive than sealed lead-acid batteries and require more complex charging circuits


Application

The charging time of Battery for UPS computer usually depends on the capacity of the battery. Higher capacity batteries take longer to charge. It is crucial to choose a battery that can be charged quickly to ensure it recovers more quickly after a power outage. Additionally, battery shelf life is a key characteristic to consider. The shelf life of a battery is the length of time a battery can be stored without losing its ability to charge. In general, UPS computer batteries have an average shelf life of 3-5 years, depending on the type of battery and its use.


You Might Also Like